Table 1. Crown Up Fault Troubleshooting Procedures -- Continued
Table 1. Crown Down Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  635    636    637    638    639  640  641    642    643    644    645  
img
. . . . .
TM 5-3895-385-23-1
0156
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
CROWN DOWN FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0376, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0451, Vol 3
References
Equipment Conditions
WP 0180
Engine off (TM 5-3895-385-10)
WP 0312, Vol 2
Hydraulic oil cool (TM 5-3895-385-10)
WP 0373, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Crown Down Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Start BMPM engine (TM 5-3895-
screen.
385-10).
2. Attempt to lower screed crown
using keypad (TM 5-3895-385-
10).
3. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next
malfunction.
0156-1