AUGER DOWN FAULT
Table 1. Auger Down Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  430    431    432    433    434  435  436    437    438    439    440  
img
TM 5-3895-385-23-1
0096
Table 1. Auger Down Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Press auger down key on
pedestal top (TM 5-3895-385-
10).
4. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3,) between pin 1 and 2 on W10
Volts Direct Current (VDC),
J4 (WP 0451, Vol 3, Figure 27)
replace auger lift hydraulic
while pressing auger down key
solenoid (WP 0312, Vol 2).
on pedestal top (TM 5-3895-385-
10).
2. If voltage reads below 22 VDC,
turn keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next test.
5. Disconnect main wiring harness
W1 J38 from main manifold
wiring harness W10 J2 (WP
0451, Vol 3, Figure 27).
6. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10). Do not start engine.
7. Press auger lower key on
pedestal top (TM 5-3895-385-
10).
8. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3,) from W1 J38 Pin 11 (WP
VDC, turn keyless engine switch
0451, Vol 3, Figure 1) to a
to the OFF position (TM 5-3895-
known good ground while
385-10), and replace main
pressing auger down key on
manifold wiring harness (WP
pedestal assembly.
0376, Vol 2).
2. If voltage reads below 22 VDC,
turn keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next
malfunction.
0096-2