TM 5-3895-385-23-1
0096
Table 1. Auger Down Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Screed controller (Electronic
1. Disconnect main wiring harness
Control Module (ECM)) has
W1 J1 from screed controller
damage or loose pin.
module ECM (WP 0451, Vol 3,
Figure 1).
2. Check screed controller module
1. If screed controller module ECM
ECM for damage or loose pin.
has damage or loose pin,
replace screed controller module
ECM (WP 0401, Vol 2).
2. If no damage is found, proceed
to next malfunction.
4. Main wiring harness has an
1. If continuity is present, proceed
open circuit.
Vol 3,) between main wiring
to next malfunction.
harness W1 J1 Pin 32 and main
wiring harness W1 J38 Pin 11 (WP
0451, Vol 3, Figure 1).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
5. Main wiring harness has a short
1. If continuity is present, replace
circuit.
Vol 3,) between main wiring
main wiring harness (WP 0373,
harness W1 J1 Pin 32 and all other
Vol 2).
pins on the main wiring harness W1
J1 (WP 0451, Vol 3, Figure 1).
2. If no continuity is present,
replace screed controller module
ECM (WP 0401, Vol 2).
END OF WORK PACKAGE
0096-3/4 blank