Table 1. SPN#167, FMI#18 ? Electrical Charging System Voltage Low --Moderately Severe Level -- Continued
SPN#168, FMI#16 ? ENGINE ELECTRONIC CONTROL MODULE (ECM) SUPPLY VOLTAGE ABOVEMAXIMUM SYSTEM VOLTAGE LEVEL

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  187    188    189    190    191  192  193    194    195    196    197  
img
TM 5-3895-385-23-1
0044
Table 1. SPN#167, FMI#18 ― Electrical Charging System Voltage Low --
Moderately Severe Level -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Check active engine fault
1. If fault code SPN#167, FMI#18
screen for fault code SPN#167,
is displayed, turn keyless
FMI#18.
engine switch to the OFF
position (TM 5-3895-385-10). It
is possible that another fault
exists or that another
troubleshooting procedure
applies. If this was the first time
through the task, restore to
original condition, and restart
troubleshooting at malfunction
1.
2. If fault code SPN#167, FMI#18
is not displayed, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10).
No fault present; restore
equipment to original condition.
END OF WORK PACKAGE