TM 5-3895-373-34
2.62
REPLACE CONVEYOR DRAG PLATES AND ENGINE INSULATION PAN - Continued.
B.
CLEAN.
1.
CLEAN ALL METAL PARTS.
Cleaning solvent, P-D-680, is TOXIC and
flammable. Wear protective goggles and
gloves. Use only in a well ventilated area.
Avoid contact with skin, eyes, and clothes,
and do not breathe vapors. Keep away from
heat or flame. Never smoke when using
solvent; the flashpoint for Type III cleaning
solvent is 200°F (93,3°C). Failure to do so
may result in injury or death to personnel.
If personnel become dizzy while using
cleaning solvent, immediately get fresh air
and medical help. If solvent contacts skin or
clothes, flush with cold water. If solvent
contacts eyes, flush eyes with water and get
immediate medical attention.
a.
Clean all metal parts in contact with
conveyor drag plates with cleaning solvent.
Use a wire scratch brush to remove hard
deposits.
b.
Clean cap screw and bolt holes in main
frame
supports
to
remove
any
hard
deposits.
2.
CLEAN MOUNTING HARDWARE.
Thread locking compound solvent can cause
eye damage. Wear safety goggles/glasses
when using. Avoid contact with eyes. If
solvent contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Use thread locking compound solvent to
remove thread locking compound from all
fasteners.
b.
Dry parts with a cleaning cloth.
GO TO NEXT PAGE
2-856