TM 5-3895-373-34
C.
INSTALL - Continued.
5.
INSTALL PLUGS AND ELBOWS.
WARNING
Pipe sealant can cause eye damage
or skin irritation. Wash after skin
contact.
Wear
safety
goggles/glasses
when
using.
Avoid contact with eyes or skin. If
sealant contacts eyes, flush eyes
with
water
and
get
immediate
medical attention.
CAUTION
Coat
only
leading
threads
of
hydraulic components with pipe
sealant. Excessive amounts of pipe
sealant may contaminate hydraulic
system.
NOTE
Use of 1-1/2 in. (Item 116, Appendix
D) and 1-1/4 in. (Item 115, Appendix
D) combination wrenches will be
required to perform this procedure.
a.
Apply pipe sealant to leading threads of pipe
plugs (40 and 47) and elbows (33 through 38,
41, 43, and 44).
b.
Install plugs (47).
CAUTION
Check valve (45) must be installed
with flow directed into hydraulic
reservoir. Improper installation of
check valve will cause hydraulic
system failure.
c.
Install port #1 elbow (46), check valve (45),
and elbow (44). Check valve flow must be
directed into hydraulic reservoir. Elbow (44)
must point straight down.
d.
Install port #2 elbow (43), pipe coupling (42),
and elbow (41). Elbow (41) must point straight
down.
e.
Install port #3 and #4 elbows (33 and 34). Aim
elbows to the right 45°.
f. Install plug (40) at reservoir port #5. 45° left.
g. Install port #6 and #7 elbows (35 and 36). Installed
elbows must point straight out.
h. Install port #8 elbow (38) with attached tee (39). Installed
elbow must point 45O left. Tee points up and 45° to the
left.
i. Install port #9 elbow (37). Installed elbow must point
GO TO NEXT PAGE
2-713