TM 5-3895-373-34
2.53
REPLACE/REPAIR HYDRAULIC RESERVOIR COMPONENTS - Continued.
A.
REMOVE - Continued.
10.
REMOVE SIGHT LIQUID INDICATOR.
a.
Remove and discard ported screws (57) and
sight liquid indicator (58).
b.
Remove and discard preformed packings (59).
c.
Discard all parts. Replacement sight liquid
indicator includes all new parts.
11.
REMOVE DRAIN PLUG (60), DRAIN HOSE
(61), AND ELBOW (62).
B.
CLEAN.
1.
CLEAN
METAL
HYDRAULIC
RESERVOIR
COMPONENTS.
WARNING
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
III cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Rinse metal parts with cleaning solvent. Use a
pipe cleaner or culture swabs to remove foreign
material from inside of pipes and pipe fittings.
b.
Saturate areas with gasket residue remaining
and scrape away any residue.
GO TO NEXT PAGE
2-708