TM 5-3895-373-34
2.53
REPLACE/REPAIR HYDRAULIC RESERVOIR COMPONENTS - Continued.
C.
INSTALL - Continued.
9.
INSTALL TEST MANIFOLD.
WARNING
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Install lockwasher (10) onto hex head cap screw
(9). Apply thread locking compound to threads
of cap screws.
b.
Position
test
manifold
(11)
onto
hydraulic
reservoir and secure with hex head cap screws
(9). Tighten hex head cap screws to 37 lb-ft (50
N.m).
c.
Reinstall hydraulic pressure gauges on test
manifold.
10.
INSTALL HYDRAULIC HOSES.
WARNING
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
NOTE
Use of 1-1/2 in. (Item 116, Appendix
D) and 1-1/4 in. (Item 115, Appendix
D) combination wrenches will be
required to perform this procedure.
a.
Apply hydraulic fitting sealant to threads of port
#1, 2, 3, and 4 fittings.
b.
Connect oil cooler hose (5) to port #1 elbow.
c.
Connect tagged hoses (6 through 8) to elbows
installed at reservoir ports #2, 3, and 4.
GO TO NEXT PAGE
2-718