TM 5-3895-373-34
B.
CLEAN.
Cleaning solvent, P-D-680, is TOXIC and
flammable. Wear protective goggles
and gloves. Use only in a well ventilated
area. Avoid contact with skin, eyes, and
clothes, and do not breathe vapors.
Keep away from heat or flame. Never
smoke
when
using
solvent;
the
flashpoint for Type III cleaning solvent is
200°F (93,3°C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using
cleaning solvent, immediately get fresh
air and medical help. If solvent contacts
skin or clothes, flush with cold water. If
solvent contacts eyes, flush eyes with
water
and
get
immediate
medical
attention.
1.
RINSE
ALL
METAL
PARTS
IN
CLEANING
SOLVENT.
Compressed air used for cleaning
purposes will not exceed 30 psi (207
kPa). Use only with effective chip
guarding
and
personal
protective
equipment (goggles/face shield and
gloves).
Failure
to
take
proper
precautions may result in severe injury
or loss of vision.
2.
USE 30 PSI (207 kPa) MAXIMUM COMPRESSED
AIR TO REMOVE ANY FOREIGN MATTER FROM
VALVE BODY, THREADED SURFACES, BORES,
AND SEAL GROOVES.
3.
DRY ALL PARTS WITH A CLEAN, LINT-FREE
CLOTH.
GO TO NEXT PAGE
2-623