TM 5-3895-373-34
2.44
REPAIR STACK VALVE AND STACK VALVE WIRING HARNESS - Continued.
A.
REMOVE - Continued.
9.
REMOVE
VALVE
ELECTRICAL
COIL
CONNECTOR FROM STACK VALVE WIRING
HARNESS.
a.
Unscrew screw (50) from connector body (51).
b.
Unscrew packing nut (52) and slide nut back
along harness wiring.
c.
Use petrolatum to lubricate harness wiring inside
packing nut port of connector body (51). Push
harness wiring forward, into connector body.
d.
Pry contact housing (53) from connector body
(51) with small screwdriver. When contact
housing pops out, pull housing and attached
harness wiring from connector body.
e.
Tag lead wires with mating terminal number (1,
2, or 3). Loosen crimping screws securing
harness leads to terminals in contact housing
(53). Remove harness wiring from contact
housing and connector body.
f.
Slide packing (54), packing retainer (55), and
packing nut (52) from wiring harness. Discard
all connector parts.
GO TO NEXT PAGE
2-610