TM 5-3895-373-34
2.17
DIESEL ENGINE REPAIR - Continued.
E.
INSTALL Continued.
Uncured gasket sealing compound
can
cause
eye
damage
or
skin
irritation. Avoid contact with eyes
and skin. If compound contacts eyes,
flush eyes with water for 15 minutes
and get immediate medical attention.
If sealing compound contacts skin,
remove from skin with a dry cloth or
paper towel and wash thoroughly
with
soap
and
water.
Sealing
compound releases acetic acid while
curing.
Use
with
adequate
ventilation.
z.
Apply gasket sealing compound to both sides of
gasket (15).
aa.
Install gasket (15), cover (14), lockwashers (13),
and nuts (12).
ab.
Apply gasket sealing compound to both sides of
gasket (11).
ac.
Install
gasket
(11),
adapter
plate
(10),
lockwashers (9), and hex head cap screws (8).
ad.
Apply gasket sealing compound to both sides of
gasket (19).
ae.
Install gasket (19), hose flange (18), flat washers
(17), and bolts (16).
af.
Install alternator support bracket (7) and secure
with washers (6), lockwashers (5), and hex nuts
(4).
ag.
Install crankshaft pulley (3), aligning crankshaft
pulley
timing
mark
with
timing
mark
on
crankshaft assembly.
ah.
Install thrust block (2) and bolts (1). Tighten
bolts to 70 lb-ft (95 N.m).
GO TO NEXT PAGE