TM 5-3895-373-34
2.16
ENGINE REPLACEMENT - Continued.
C.
INSTALL - Continued.
24.
APPLY ELECTRICAL INSULATING COMPOUND
TO
INDUCTION
HEATER
(66).
INSTALL
INDUCTION HEATER WIRE 165 (65) ONTO
INDUCTION HEATER WIRE TERMINAL.
25.
APPLY ELECTRICAL INSULATING COMPOUND
ONTO END OF HARNESS CONNECTOR (63).
RECONNECT
HARNESS
CONNECTOR
TO
TURBOSUPERCHARGER
PRESSURE
TRANSMITTER CONNECTOR (64).
26.
INSTALL AIR HOSE (72) AND CLAMP (71) ONTO
TURBOSUPERCHARGER
(73)
AIR
INTAKE.
TIGHTEN CLAMP.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
27.
APPLY
HYDRAULIC
FITTING
SEALANT
TO
THREADS OF TEE (70). INSTALL AIR CLEANER
SERVICE INDICATOR KNOB HOSE (69) ONTO
TEE.
28.
APPLY ELECTRICAL INSULATING COMPOUND
ONTO
END
OF
HARNESS
CONNECTOR
(67).RECONNECT HARNESS CONNECTOR TO
AIR PRESSURE TRANSMITTER CONNECTOR
(68).
GO TO NEXT PAGE