TM 5-3895-373-34
C.
INSTALL - Continued.
20.
INSTALL
GROUND
WIRE
G201
ONTO
HYDRAULIC RESERVOIR MOUNTING BRACKET.
a.
Remove hex head cap screw (80) and flat
washer (83).
b.
Install lockwasher (81), ground wire G201 (82),
and flat washer (83) onto hex head cap screw
(80).
c.
Install hex head cap screw (80) into hydraulic
reservoir mounting bracket (84). Tighten hex
head cap screw 37 lb-ft (50 Nm).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
d. Apply electrical insulating varnish to installed flat
washer (83), ground wire G201 (82), lockwasher
(81), and hex head cap screw (80).
21. APPLY ELECTRICAL INSULATING COMPOUND
TO END OF HARNESS CONNECTOR (78) AND
RECONNECT
TO
THROTTLE
ACTUATOR
CONNECTOR (79).
22. APPLY ELECTRICAL INSULATING COMPOUND
TO END OF HARNESS CONNECTORS (76) AND
RECONNECT TO ENGINE OIL PRESSURE
TRANSMITTER CONNECTOR (77).
23. APPLY ELECTRICAL INSULATING COMPOUND
TO END OF HARNESS CONNECTOR (74) AND
RECONNECT
TO
ENGINE
OIL
FILTER
DIFFERENTIAL
PRESSURE
TRANSMITTER
CONNECTOR (75).
GO TO NEXT PAGE
2-141