TM 5-3895-373-34
2.16
ENGINE REPLACEMENT - Continued.
C.
INSTALL - Continued.
16.
RECONNECT HARNESS CONNECTORS TO
LEFT AND RIGHT FORWARD WORK LIGHT
CONNECTORS.
a.
Apply electrical insulating compound to male end
of
harness
connector
(93)
and
reconnect
harness connectors to left and right forward work
light connectors (95).
b.
Secure harness connectors (93) to mounting
bracket (94) with tie wraps (92).
c.
Remove hex head cap screw (96) from mounting
bracket (94).
Thread locking compound can cause
eye damage. Wear safety goggles
when
using
thread
locking
compound. Avoid contact with eyes.
If compound contacts eyes, flush
eyes with water and get immediate
medical attention.
d.
Install lockwashers (97) onto hex head cap
screws (96) and coat threads of cap screws with
thread locking compound.
e.
Install hex head cap screw (96), lockwasher (97)
and ground wire (98) onto mounting bracket
(94). Tighten to 20 lb-ft (27 Nm).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
f.
Apply electrical insulating varnish to installed
ground wire (98), lockwasher (97), and hex head
cap screw (96).
GO TO NEXT PAGE
2-138