TM 5-3895-373-34
C.
INSTALL - Continued.
36.
INSTALL
ELECTRICAL
CONNECTIONS
ON
ALTERNATOR.
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
a.
Remove and discard self-locking hex nut (32).
b.
Install DCA ground wire 330 (33) onto alternator
(27) pivot bolt and secure with selflocking hex
nut (32). Coat DCA ground wire 330 terminal
with electrical insulating varnish.
c.
Coat male end of W terminal on alternator with
electrical insulating compound and install wire
102 (31) to the W terminal on alternator (27) and
plug in.
d.
Install wire 160 (30) and wire 329 (29) onto B+
terminal on alternator (27) and secure with
lockwasher (25) and hex nut (28).
e.
Install wire 328 (26) onto D+ terminal on
alternator (27) and secure with lockwasher (25)
and hex nut (24).
f.
Coat wire 160 (30), wire 329 (29), and wire 328
(26) terminals with electrical insulating varnish.
GO TO NEXT PAGE
2-147