TM 5-3895-373-34
A.
REMOVE Continued.
34.
DISCONNECT HYDRAULIC HOSES FROM RIGHT
PROPULSION PUMP.
a.
Place machinery wiping towels underneath right
propulsion pump (164).
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
b.
Tag suction hose (165). Disconnect suction
hose connected to right propulsion pump (164)
elbow (166) and hydraulic reservoir port #6. Cap
elbows and plug suction hose ends.
c.
Tag and disconnect case drain hose (167)
connected to right propulsion pump (164)
straight adapter (168). Plug hose end and cap
straight adapter.
d.
Using combination wrench (Item 115, Appendix
D), tag and disconnect propulsion pump port A
hose (169) connected to right propulsion pump
(164) elbow (170).
Plug hose end and cap elbow.
e.
Using combination wrench (Item 115, Appendix
D), tag and disconnect propulsion pump port B
hose (171) connected to right propulsion pump
(164) elbow (172).
Plug hose end and cap elbow.
f.
Tag and disconnect charge pump port A hose
(173) connected to right propulsion pump (164)
elbow (174).
Plug hose end and cap elbow.
g.
Tag and disconnect charge pump port B hose
(175) connected to right propulsion pump (164)
elbow (176). Plug hose end and cap elbow.
GO TO NEXT PAGE
2-101