TM 5-3895-373-34
A.
REMOVE Continued.
29.
DISCONNECT ENGINE OIL COOLER HOSES.
a. Loosen hose clamp (121) and tag and remove
coolant hose (122)
from thermostat
housing adapter (123).
b.
Loosen hose clamp (124) and tag and remove
coolant hose (125) from engine block coolant
gallery fitting (126).
c.
Remove hose clamps (121) and (124). Set
aside for reassembly during installation.
Hydraulic
oil
can
be
moderately
flammable and can be irritant to the
skin, eyes, and respiratory system.
Avoid prolonged exposure. Eye
protection and rubber gloves must be
worn when working with hydraulic
oil.
30.
DRAW HYDRAULIC OIL FROM HYDRAULIC OIL
HOSES AND HYDRAULIC PUMPS BACK INTO
HYDRAULIC
RESERVOIR
USING
VACUUM
SUCTION METHOD PER PARAGRAPH 2.54.
31.
DISCONNECT HYDRAULIC HOSES FROM LEFT
AND RIGHT AUXILIARY PUMPS.
a.
Place machinery wiping towels underneath left
and right auxiliary pumps.
b.
Using combination wrench (Item 115,
Appendix D), tag and disconnect suction hose
(127) connected to left auxiliary pump (128)
intake straight adapter (129) and hydraulic
reservoir port #8A. Plug suction hose ends and
cap straight adapter and hydraulic reservoir
elbows.
c.
Tag and disconnect outlet hoses (130 and 131)
connected to left auxiliary pump (128) straight
adapters (132 and 133). Plug outlet hose ends
and cap straight adapters.
GO TO NEXT PAGE
2-97