TM 5-3895-373-34
C.
INSTALL Continued.
6.
CONNECT
WIRING
TO
THERMOSTAT
HOUSING.
a.
Install wire 111 (31) to terminal C on high
temperature shutdown sensor (32). Secure with
self-locking screw (30).
b.
Install wire 151 (33) to terminal NC on high
temperature shutdown sensor (32).
c.
Install wire 152 (34) to terminal NO on high
temperature shutdown sensor (32).
GO TO NEXT PAGE
2-77