TM 5-3895-373-20C. INSTALL.Hydraulic fitting sealant can cause eyedamage or skin irritation. Wash afterskin contact. Wear safetygoggles/glasseswhen using. Avoidcontact with eyes or skin. If sealantcontacts eyes, flush eyes with water andget immediate medical attention.1. APPLY HYDRAULIC FITTING SEALANT TOELBOW (6).2. INSTALL VIBRATION RELIEF VALVE (7) BYCONNECTING STRAIGHT ADAPTER (5) TOELBOW (6) ON AUXILIARY VIBRATION PUMP(8). POSITION RELIEF VALVE SO THATWHEN TIGHTENED, CAP NUT (9) IS ON TOP.SEE THE ILLUSTRATION FOR CORRECTPOSITIONING.3. APPLY HYDRAULIC FITTING SEALANT TOEXPOSED THREADS OF ELBOW (3) ANDSTRAIGHT ADAPTER (4).4. CONNECT HOSES (1 AND 2) TO ELBOW (3)AND STRAIGHT ADAPTER (4). TIGHTENHOSES.NOTEFOLLOW-ON-TASKS: Install right access cover per TM 5-3895-373-10.Close right access door per TM 5-3895-373-10.END OF TASK13-25