TM 5-3895-373-20
C.
INSTALL - Continued.
7.
INSTALL SCREED GUARD PLATES ON MAIN
WALKWAY STEP.
WARNING
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Install flat washers (16) onto bolt (14) and
apply thread locking compound (Item 13,
Appendix C) to bolts.
b.
Install screed guard plates (17) on supports
of main walkway step (18) and secure with
bolts (14), flat washers (16), and hex nuts
(15).
c.
Tighten hex nuts (15) to 19 lb-ft (26 Nm).
GO TO NEXT PAGE
11-31