TM 5-3895-373-20C.INSTALL - Continued.WARNINGThread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.o.Place flat washers (31) onto hex head capscrews (29) and apply thread lockingcompound (Item 12, Appendix C) to threadsof hex head cap screws.p.Install decontamination can bracket (28) toleft side of screed handrail (25) and securewith hex head cap screws (29), flat washers(31), and hex nuts (30). Tighten hex nutsto 37 lb-ft (50 N•m).q.Install strap (26) onto decontamination canbracket (28).r.Place decontamination can (27) indecontamination can bracket (28). Securedecontamination can with strap (26).5.INSTALL AND ADJUST FIREEXTINGUISHER BRACKET.a.Install flat washers (24) onto hex head capscrews (22).b.Apply thread locking compound (Item 12,Appendix C) to threads of hex head capscrews (22).c.Install fire extinguisher bracket (21) on rightside of screed handrail (25) and secure withhex head cap screws (22), flat washers(24), and hex nuts (23). Tighten hex nutsto 37 lb-ft (50 N•m).GO TO NEXT PAGE11-29