TM 5-3895-373-20
8.2.
REPLACE HYDRAULIC OIL COOLER - Continued.
C. INSTALL.
1.
INSTALL PIPE PLUGS AND STRAIGHT
ADAPTERS.
WARNING
Pipe sealant can cause eye damage
or skin irritation. Wash after skin
contact. Wear safety goggles/glasses
when using. Avoid contact with eyes
or skin. If sealant contacts eyes,
flush
eyes
with
water
and
get
immediate medical attention.
a.
Apply pipe sealant to threads of pipe plugs
(12) and pipe threads of straight adapters
(7).
b.
Install and tighten pipe plugs (12) in top of
hydraulic oil cooler (2).
c.
Using a 1-3/8 in. combination wrench,
install and tighten straight adapters (7) in
bottom of hydraulic oil cooler (2).
GO TO NEXT PAGE
8-6