TM 5-3895-373-20
7.6.
REPAIR/REPLACE OPERATOR CONTROL CONSOLE ASSEMBLY - Continued.
C.
INSTALL - Continued.
11.
INSTALL GAUGE PANEL LEFT AND RIGHT
SEALS AND ACCESS DOORS AND COVER
PLATE
ONTO
OPERATOR
CONTROL
CONSOLE.
WARNING
Adhesive is TOXIC and extremely
flammable. Keep away from heat,
sparks, and open flames. Use only in
well ventilated areas. Do not breathe
vapors or swallow and avoid contact
with eyes and skin. Failure to do so
may result in injury or death to
personnel.
If personnel become dizzy while
using adhesive, immediately get fresh
air
and
medical
attention.
If
personnel swallow adhesive, do not
induce vomiting. Get immediate
medical
attention.
If
adhesive
contacts eyes, flush eyes with water
for 15 minutes and get immediate
medical
attention.
If
adhesive
contacts skin, wash thoroughly with
soap and water.
a.
Apply adhesive to cover plate (40) seal
area.
b.
Install cover plate seal (41) onto cover plate
(40).
c.
Apply adhesive to gauge panel left access
door (32) and gauge panel right access
door (33) seal area.
d.
Install door seals (38 and 37) onto gauge
panel left access door (32) and gauge
panel right access door (33).
e.
Install cover plate (40) and secure with
button head cap screws. (39). Tighten cap
screws.
NOTE
For repair and adjustment of door
latches, refer to paragraph 11.2.
f.
Install gauge panel left access door (32)
and gauge screws panel right access door
(33), both in the open position, and secure
with screws (36), flat washers (35), and hex
nuts (34). Tighten hex nuts.
g.
Close gauge panel left and right access
doors (32 and 33) per TM 5-3895-373-10.
GO TO NEXT PAGE
7-50