TM 5-3895-373-206.6.REPLACE RADIATOR FAN - Continued.B.INSTALL.Thread locking compound solventcan cause eye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If solvent contactseyes, flush with water and getimmediate medical attention.1.CLEAN THREADS OF BOLTS (1) WITHTHREAD LOCKING COMPOUND SOLVENT.2.INSTALL WATER PUMP PULLEY (5), SPACER(4) AND RADIATOR FAN (3).3.INSTALL FLAT WASHERS (2) ONTO BOLTS(1).Thread locking compound can causeeye damage. Wear safetygoggles/glasses when using. Avoidcontact with eyes. If compoundcontacts eyes, flush eyes with waterand get immediate medical attention.4.APPLY THREAD LOCKING COMPOUND TOTHREADS OF BOLTS (1).5.INSTALL BOLTS (1) AND TIGHTEN TO 21LBFT (28 N•m).NOTEFOLLOW-ON TASKS: Install and adjust fan belt per paragraph 6.7.Install radiator and radiator shroud per paragraph 6.2.Install hydraulic oil cooler per paragraph 8.2.END OF TASK6-18