TM 5-3895-373-20
6.6.
REPLACE RADIATOR FAN - Continued.
B.
INSTALL.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush with water and
get
immediate medical attention.
1.
CLEAN
THREADS
OF
BOLTS
(1)
WITH
THREAD LOCKING COMPOUND SOLVENT.
2.
INSTALL WATER PUMP PULLEY (5), SPACER
(4) AND RADIATOR FAN (3).
3.
INSTALL FLAT WASHERS (2) ONTO BOLTS
(1).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
4.
APPLY THREAD LOCKING COMPOUND TO
THREADS OF BOLTS (1).
5.
INSTALL BOLTS (1) AND TIGHTEN TO 21
LBFT (28 Nm).
NOTE
FOLLOW-ON TASKS: Install and adjust fan belt per paragraph 6.7.
Install radiator and radiator shroud per paragraph 6.2.
Install hydraulic oil cooler per paragraph 8.2.
END OF TASK
6-18