6.5.
REPLACE WATER PUMP - Continued.
B.
CLEAN.
1.
CLEAN PUMP CAP.
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
Ill cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Use a cleaning cloth soaked with cleaning
solvent to clean pump cap.
b.
Use a parts cleaning brush and cleaning
solvent to remove any hard deposits and
carbon buildup.
Use caution when scraping gasket
sealing surfaces with putty knife.
Putty
knife
may
score
sealing
surfaces and debris may fall into
open ports. Failure to do so may
result in poor seal and equipment
damage.
c.
Use a putty knife, if necessary, to remove
any gasket material from sealing surfaces.
Do not score the sealing surface or allow
any gasket material to fall into open ports
on engine.
GO TO NEXT PAGE
6-14