TM 5-3895-373-20
2.24.3. SCREED REMOVAL AND INSTALLATION - Continued.
B.
INSTALL - Continued.
4.
RECONNECT
SCREED
FUEL
AND
HYDRAULIC HOSES.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
a.
While another person holds drip pan to collect
hydraulic oil, disconnect high pressure caps from
elbows at ports #6 and #7. Allow all oil to drain
from open elbows. Dispose of oil in accordance
with local procedures.
b.
Remove plugs from hoses (3 through 9) and
caps from mating elbows at ports #1 through #5.
c.
Wipe threads of hose and port elbows dry with
clean cleaning cloths.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
d.
Apply hydraulic fitting sealant to threads of
elbows at ports #1 through #7. Install and
tighten hoses (3 through 9).
GO TO NEXT PAGE
2-464