TM 5-3895-373-202.24.3. SCREED REMOVAL AND INSTALLATION - Continued.B.INSTALL - Continued.4.RECONNECT SCREED FUEL ANDHYDRAULIC HOSES.Hydraulic oil can be moderatelyflammable and can be an irritant tothe skin, eyes, and respiratorysystem. Avoid prolonged exposure.Eye protection and rubber glovesmust be worn when working withhydraulic oil.a.While another person holds drip pan to collecthydraulic oil, disconnect high pressure caps fromelbows at ports #6 and #7. Allow all oil to drainfrom open elbows. Dispose of oil in accordancewith local procedures.b.Remove plugs from hoses (3 through 9) andcaps from mating elbows at ports #1 through #5.c.Wipe threads of hose and port elbows dry withclean cleaning cloths.Hydraulic fitting sealant can causeeye damage or skin irritation. Washafter skin contact. Wear safetygoggles/glasses when using. Avoidcontact with eyes or skin. If sealantcontacts eyes, flush eyes with waterand get immediate medical attention.d.Apply hydraulic fitting sealant to threads ofelbows at ports #1 through #7. Install andtighten hoses (3 through 9).GO TO NEXT PAGE2-464