TM 5-3895-373-10
Fuel is very flammable and can
explode easily.
To avoid serious injury or death:
Always wear safety glasses/goggles
at all times.
Never operate the spray washdown
system
with
the
screed
burners
operating.
Keep fuel away from open flame or
any spark (ignition source).
Keep at least a B-C fire extinguisher
within easy reach when working with
fuel or on a fuel system.
Post signs that read "NO SMOKING
WITHIN 50 FEET" when working with
open fuel lines or fuel tanks.
Always
wear
personal
protective
equipment such as a face shield,
protective clothing, and gloves.
(16)
Clean the trailing edge of main screed
plate (33) and left and right extension
screed plates (34). Ensure paving
material does not build up in recesses of
screed frame.
(17)
Place screed fuel pump switch to the
down, OFF position.
(18)
Close screed burner fuel shutoff valve (10)
by turning valve handle to the 3 oclock
position.
h
Disconnect the fuel spray wand assembly (8)
from quick disconnect coupling (9) on screed
burner manifold (11). Install protection cover to
quick disconnect coupling.
i
Lift and push screed steps forward until fully
seated.
j
Coil up and return spray wand assembly to fuel
spray wand hanger to the right of the operator
platform.
k
Start paving machine engine per paragraph
2.10.
3-32