17. SCREED WILL NOT LOWER.
Step 1. Check screed travel lock valve.
WARNING
Do not open the screed travel lock valve if anyone is near or under the screed. The screed can fall
rapidly when the screed travel lock valve is opened. The falling screed can cause severe injury or
death.
Carefully open screed travel lock valve per paragraph 2.23.1.
Step 2. Check position of CB5.
Reset CB5. If CB5 trips a second time, inform supervisor of problem.
Step 3. If screed travel lock valve is open and circuit breaker CB5 is not tripped, inform supervisor of problem.