TM 53895371-24 & PTable 2-2.Troubleshooting (Continued).MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION9. SPRAY LACKS PRESSURE (Continued):step 3.Discharge strainer plugged.Remove and clean (para 12-6).10. APPLICATION RATE VARIES:Step 1.Improper reading of tank contents.Use measuring stick for accurate readings. Tank must be level when readingmeasuring stick.Step 2.Defective pump tachometer.Repair or replace (para 2-25).step 3.Defective recording bitumeter.Repair or replace (para 2-25).step 4.Catch lever on quadrant not pulled.Pull catch lever out.step 5.Discharge strainer plugged.Remove and clean discharge strainer on pump outlet (para 12-6).Step 6.Hydrostatic control not firmly positioned.Adjust and tighten (TM 5-3895-371-10).step 7.Hydrostatic override control partially engaged.Return override to neutral position.11.DIFFICULTY IN RAISING SPRAY BAR END SECTIONS IN VERTICAL POSITIONS:step 1.Hinge joint inoperative.Adjust or replace retaining rings and packing (para 2-38).step 2.Damaged linkage Repair or replace linkage (para 2-38).2-10