TM 5-3895-371-24 & P
Table 2-2. Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
QUADRANT LEVER SLOWS OR STOPS PUMP WHEN MOVING FROM CIRCULATE IN
TANK TO CIRCULATE IN BAR (Continued):
Step 2.
Linkage out of adjustment.
Check relation of quadrant lever position with nozzle lever position and adjust
as needed (para 2-29).
Step 3.
Transfer valve in hand spray position.
Set transfer valve to distribute position.
7. SPRAY FOGS:
step 1.
Pump speed too fast for size of nozzle.
Check Circulating in Tank in TM 53895371-10 for proper relationship.
8. SPRAY STREAKS:
step 1.
Pump speed too slow.
Check Circulating in Tank in TM 53895371-10 for proper relationship.
Step 2.
Nozzles not at proper angle.
Adjust with nozzle wrench (refer to TM 5-3895-371-10).
step 3.
Spray bar at improper height above ground.
Adjust spray bar to give nozzle height 12 in. (30.48 cm) above road.
step 4.
Material temperature too low.
Heat material to highest temperature recommended for spraying material.
9. SPRAY LACKS PRESSURE:
step 1.
Pump speed too slow.
Check Circulating in Tank (refer to TM 5-3895-371-10) for proper relationship.
step 2.
One of control valves in incorrect position.
Lift quadrant and turn valve plugs to position relative to levers (refer to TM 5-
3895-371-10).
2-9