TM 5-3895-371-24 & PTable 2-1. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES(Continued)Q-QuarterlyS-SemiannuallyA-AnnuallyB-BienniallyH-HoursM-MilesITEMINTERVALITEM TO BE INSPECTEDN O . Q S A B H Ml PROCEDURE: Check for and have repaired, filled, or adjusted as needed.BURNER FUEL SYSTEM (Continued)11Check smoke stack cover spring for damage and check operation.Replace spring if necessary.BITUMETER WHEEL ASSEMBLY1213Check air lines and fittings. If damaged, replace.Check power line and ground on solenoid for corrosion and barewires, replace defective wires.14Check that bitumeter positions itself when activated. Adjust orrepair as needed.SPRAY BAR15Check that spray bar positions itself whenever control switches areactivated. Adjust as needed.1617Check chains. Replace as necessary.Check power lines to solenoids for corrosion and bare wires. Replacedefective wires.18 Check relation of quadrant lever position with nozzle lever position.Adjust linkage as needed.192021 Check recording bitumeter cable operation and service it.Check pump tachometer cable and service it.Check air control reservoir. Open drain cock to let out condensation.2-5