Table 3-2 Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
SPRAY FOGS
Step 1.
Pump speed too fast for size of nozzle
relation
5.
SPRAY STREAKS.
Step 1.
Pump speed too slow
speed
Step 2.
Nozzles not at proper angle
Step 3.
Spray bar at improper height above ground
Adjust spray bar to give nozzle height of 12 in. above
Step 4.
Material temperature too low
Heat material to highest temperature recommended for
spraying material
6.
SPRAY LACKS PRESSURE.
Step 1.
Pump speed too slow
speed.
Step 2.
One of the control valves in incorrect position
Lift quadrant and turn valve plugs to position corresponding
Step 3.
Discharge strainer plugged
7.
APPLICATION RATE VARIES.
Step 1.
Improper reading of tank contents
Using measuring stick (11, fig B-1) for accurate readings