3-7. Cleaning and Servicing.
Cleaning and servicing the distributor is extremely important. A buildup of bituminous material will cause major problems
in operation, equipment failures, and the need for frequent maintenance. Always use an approved cleaning solvent and
replace any broken or damaged components. Follow the procedures in this section and you can keep your distributor in
good operating condition.
The fuel tank is mounted on the right side of the distributor and has a 36 gal capacity.
a
Inspect tank cap (1) for a tight fit and see that gasket (2) is clean and in place.
b
Inspect vent holes in the center of tank cap (1) for any obstructions that would prevent air from
replacing fuel used.
a.
Removal.
(1)
Loosen wing nut (2) and remove cap assembly (1) from air cleaner body (4)
(2)
Remove filter screen (3) from cap assembly (1)
(3)
Remove air cleaner body (4) from blower body (6)
(4)
Remove gasket (5)
b.
Cleaning
(1) Remove oil from air cleaner body (4)
3-13