TM 5-3895-356-14&P
ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES
Q-QUARTERLY
S-SEMIANNUALLY
A-ANNUALLY
B-BIENNIALLY
H-HOURS
MI-MILES
ITEM TO BE INSPECTED
ITEM NO
INTERVAL
PROCEDURE: CHECK FOR AND HAVE REPAIRED, FILLED, OR ADJUSTED AS NEEDED
Q
S
A
B
H
MI
PERFORM ALL OPERATOR PMCS FIRST
12
X
Check and clean burner valve strainer (2 each) (Page 57).
13
X
Check and clean pump supply line strainer. (Page 50).
14
X
Check heater burners and flues for insecure mounting. Repair as needed.
15
X
Check burner assembly air hose for leaks. Replace if damaged.
16
X
Check and service portable burner vaporizing coil and jet. If damaged, replace.
17
X
Check smoke stack cover spring for damage and check operation Replace spring i f necessary.
Bitumeter Wheel Assembly
18
X
Check air lines and fittings. If damaged, replace.
19
X
Check power line and ground on solenoid for corrosion and bare wires Replace defective wires.
20
X
Check that Bitumeter wheel positions itself when activated. Adjust or repair as needed
Blower Drive Assembly
21
X
Check blower/hydraulic drive shaft and u-joint. If damaged, replace.
22
X
Check blower drive belt. If damaged, replace. Adjust belt for 1/2 inch deflection midway between
D9