TM 5-3895-356-14&P
OPERATOR/CREW PREVENTIVE MAINTENANCE CHECKS AND SERVICES
B - BEFORE
D - DURING
A - AFTER
W - WEEKLY
M - MONTHLY
INTERVAL
ITEM TO BE INSPECTED
ITEM
PROCEDURE:CHECK FOR AND HAVE REPAIRED, FILLED
EQUIPMENT IS NOT READY/
NO
B
D
A
W
M
OR ADJUSTED AS NEEDED
AVAILABLE IF:
WARNING: When heating material, exposed flues may cause an explosion
or damage flues
a. When using lower flue to heat material, tank gage should show a minimum of 525
gallons or flue covered by at least 6 inches the full length of tank.
b. When using upper flue to heat material, tank gage should show a minimum of 825
gallons or flue covered by at least 6 inches the full length of tank
9
X
Check discharge and inlet strainers. If clogged, clean and reinstall strainers (Page 10).
Hydraulic System
10
X
Check hydraulic tank and lines for proper fluid level and/or leaks If low, fill to level line.
Class III leak.
11
X
Check hydraulic pump and controls for proper operation
Inoperative
12
X
Check that hydraulic filter suction is not in the red zone.
Indicator in red zone or in-
operative
13
X
Hydraulic oil high temperature warning Indicator in cab comes on or tank gage reaches a
temperature above 180F.
D6