TM 5-3895-356-14&P
OPERATOR/CREW PREVENTIVE MAINTENANCE CHECKS AND SERVICES
B - BEFORE
D - DURING
A - AFTER
W - WEEKLY
M - MONTHLY
INTERVAL
ITEM TO BE INSPECTED
ITEM
PROCEDURE:CHECK FOR AND HAVE REPAIRED, FILLED
EQUIPMENT IS NOT READY/
NO
B
D
A
W
M
OR ADJUSTED AS NEEDED
AVAILABLE IF:
WARNING
If moisture is present in system, do not heat material over 2000F.
CAUTION
Use gloves or insulated material when handling spray bar, sections or hoses to
prevent burns.
Spray Bar
25
X
Check that spray bar positions itself whenever control switches are activated.
Inoperative.
26
X
Check that spray bar is at correct height above road bed (12 Inches).
27
X
Clean and flush pump, spray bar and circulating system with flushing oil
D7