T 5-3895-356-14&P
P.S.I. (A) Burner or between 20 and
Should either burner "flame out"
25 P.S.I. (B) Burner, using the lower
the whole system will automatically
pressure setting for shorter tanks.
shut down. To relight, repeat the
9. Adjust fire with hand valve at
above lighting procedure.
28
Always have dry chemical type
1
burner
16. On L.P.G. burners equipped
extinguisher
available
and
in
10. Do
not
leave
burners
with the optional temperature limiting
23
condition.
unattended.
control, see instructions below.
11. Do not heat material beyond
1. Open L.P G. bottle shut-off
5
Remain clear of rotating drives when
-manufacturers
recommended
valve and allow automatic iginitors to
28
units is m operation to prevent
temperature
light pilots
becoming entangled m machine
12. Do not remove material from
2. Adjust valves at burners
tank while burners are in operation or
such that one or both burners will
Keep unit clean for safety and
22
10
automatic burner controls are set to
operate as desired.
operation.
operate
3 Set temperature limiter to desired
13. To completely shut down
level.
When heating material, position unit
18
burners, close valve at supply tank or
4. Before pushing start button
broadside to wind, if possible
bottle However, if it is desired to use
check to insure BOTH pilots are lit.
only the lower burner, the upper
DO NOT push start button unless
Use of gasoline instead of required
19
burner can be shut off by closing the
both pilots are lit and have been
kerosene or fuel oil on generating or
auxiliary hand valve on the line
operating for a minimum of one
low pressure burners will result in an
between
burners
Burners
will
minute If either pilot is not lit, wait
extreme fire hazard
continue to burn until fuel in the lines
20
has been consumed.
Allow sufficient time (approximately
Cover flues at least 6" before heating
Special Notes When burner is
30 seconds) for pilot sensors to cool
material to prevent explosion.
operating properly the first two coils,
and turn on automatic ignitors
or bottom side of burners and all of
5. Once it is confirmed that
21
Allow sufficient space in tank for
the feed lines and fittings back to the
both pilots are lit, push start button to
expansion of material when heating
pressure regulator will frost over If
light main burners At this time adjust
k
they do not frost over, it shows that
burner pressure to between 25 to 40
the burner is operating on vapor
P.S.I., using the lower pressure
22
Do not remove material from tank
instead of liquid and this must be
setting for shorter tanks
while burners are in operation or
corrected immediately or you will
6. When material in tank has reached
automatic burner controls are set to
damage the burner.
desired temperature burners will
operate
In case trouble is experienced
automatically stop
with the pressure regulator freezing
7. Burners can be relit only
Do not operate burners unattended
23
up, it is due to moisture in the gas
when material m the tank has cooled
or while vehicle Is m transit or m
and this can be overcome by adding
sufficiently for the temperature limiter
confined area.
1 pint of genuine absolute Anhydrous
to come ON and the start button is
Menthanol (99 85% pure) per 100
pushed Again check to insure both
Use torch (not match or lighter) to
gallons of fuel when tank is filled.
pilots are functioning prior to pushing
25
ignite burner for personnel safety
Always keep tank valve closed
start button
when tank or bottle is empty
8. Before moving distributor,
Ignite inside burner first Do not reach
26
14. When burners are not m
close L P G bottle shut-off valve and
across a ht burner to reignite inside
allow pilots to burn all fuel from
burner
stacks to prevent loss of heat and to
supply lines.
keep water from entering stack
When burners go out, allow flues to
27
opening
ventilate before reignition
15. On L.P.G. burners equipped
with optional automatic outfire
Do not heat
material beyond
protection, follow the standard L P G
28
manufacturers
recommended
lighting instructions, except depress
temperature
the control overide switch and
manually light the burners. After 30
to 60 seconds the safety switch
should hold and the burners will stay
lit
13