• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Radiator Cover Vent Installation
Figure 1. Hydraulic Cover Vent -- Removal.

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  1263    1264    1265    1266    1267  1268  1269    1270    1271    1272    1273  
img
. . . .
TM 5-3895-385-23-2
0429
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
HYDRAULIC COVER VENT REMOVAL AND INSTALLATION
INITIAL SETUP:
Tools and Special Tools
References
General Mechanics Tool Kit (GMTK) (WP 0440, Vol
WP 0395
3, Item 64)
Equipment Conditions
Materials/Parts
Batteries disconnected (WP 0357)
Lock washer (6) (WP 0439, Vol 3, Item 106)
Engine cool
Lock washer (10) (WP 0439, Vol 3, Item 114)
Estimated Time to Complete Task
Personnel Required
1.5 hr
91L
HYDRAULIC COVER VENT REMOVAL AND INSTALLATION
WARNING
A North American Treaty Organization (NATO) slave receptacle is mounted on the hydraulic
cover vent. The BATTERY DISCONNECT switch does not cut power to this receptacle. Use
extreme caution when removing the hydraulic cover vent. Do not touch the receptacle or cables
with hands or tools. Do not attempt to disconnect the receptacle unless the batteries have both
been disconnected. Failure to comply may cause injury or death to personnel.
CAUTION
Tag and label all electric cables and connections prior to removal. Electric cables must be
installed correctly for proper operation. Failure to comply will cause damage to equipment.
NOTE
Figures 2 and 4 illustrate the NATO slave receptacle and the hydraulic cover vent from the
reverse side.