Figure 2. Fumes Exhaust Hydraulic Motor.
Figure 3. Variable Auger Hydraulic Pump.

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  805    806    807    808    809  810  811    812    813    814    815  
img
TM 5-3895-385-23-2
0359
Fumes Exhaust Assembly Removal -- Continued.
NOTE
It will be necessary to remove cable ties from cables and hoses for access.
4. Remove eight bolts (Figure 2, Item 10), lock washers (Figure 2, Item 11), flat washers (Figure 2, Item 12),
fumes exhaust hydraulic motor (Figure 2, Item 6), fumes exhaust fan (Figure 2, Item 1), and fumes exhaust
cover (Figure 2, Item 5) from fumes exhaust housing (Figure 1, Item 2). Discard lock washers.
5. Remove two set screws (Figure 2, Item 3) from fumes exhaust fan (Figure 2, Item 1), and remove fumes
exhaust fan (Figure 2, Item 1) from fumes exhaust hydraulic motor (Figure 2, Item 6).
6. Remove two nuts (Figure 2, Item 9), lock washers (Figure 2, Item 8), flat washers (Figure 2, Item 7), and
fumes exhaust hydraulic motor (Figure 2, Item 6) from bolts (Figure 2, Item 4). Discard lock washers.
0359-5