Figure 1. Hydraulic Tank Shut Off Valves.
Figure 3. Variable Auger Hydraulic Pump.

Field Maintenance Manual For Bituminous Material Paving Machine - 2 Page Navigation
  558    559    560    561    562  563  564    565    566    567    568  
img
.
TM 5-3895-385-23-2
0323
Engine Removal -- Continued.
Figure 2. Hydraulic Pump Electrical Connectors.
CAUTION
Tag and label electrical wires and hydraulic hoses prior to removal. Electrical wires and hydraulic
hoses must be installed correctly for proper operation. Failure to comply may cause damage to
equipment.
2. Disconnect W1 J18 (Figure 2, Item 1) from connector (Figure 2, Item 2) on propulsion pump.
3. Disconnect W1 J25 (Figure 2, Item 7) from connector (Figure 2, Item 8) on propulsion pump.
4. Disconnect W1 J26 (Figure 2, Item 3) from connector (Figure 2, Item 4) on variable auger pump.
5. Disconnect W1 J27 (Figure 2, Item 5) from connector (Figure 2, Item 6) on variable auger pump.