TM 5-3895-385-23-1
0180
Table 1. Propel Controller Offline Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y3 P1
Pin B and Y3 P3 Pin B (WP
0451, Vol 3, Figure 49).
2. If no continuity is present,
replace communication
connector Y3 (WP 0386, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y3 P1
Pin C and Y3 P2 Pin C (WP
0451, Vol 3, Figure 49).
2. If no continuity is present,
replace communication
connector Y3 (WP 0386, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y3 P1
Pin C and Y3 P3 Pin C (WP
0451, Vol 3, Figure 49).
2. If no continuity is present,
replace communication
connector Y3 (WP 0386, Vol 2).
18. Communication connector Y3
1. If continuity is present, replace
has a short circuit.
0443, Vol 3) between
communication connector Y3
communication connector Y3 P1
(WP 0386, Vol 2).
Pin A and all other pins on Y3
P1 (WP 0451, Vol 3, Figure 49).
2. If no continuity is present,
proceed to next test.
1. If continuity is present, replace
0443, Vol 3) between
communication connector Y3
communication connector Y3 P1
(WP 0386, Vol 2).
Pin B and all other pins on Y3
P1 (WP 0451, Vol 3, Figure 49).
2. If no continuity is present,
proceed to next test.
0180-12