Table 1. Horn Relay Fault Troubleshooting Procedures -- Continued
Table 1. Worklight Fails to Operate Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  665    666    667    668    669  670  671    672    673    674    675  
img
. . . . . . . . . .
TM 5-3895-385-23-1
0163
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
WORKLIGHT FAILS TO OPERATE
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0277, Vol 2
Personnel Required
WP 0373, Vol 2
91L
WP 0394, Vol 2
Assistant
WP 0397, Vol 2
References
WP 0399, Vol 2
WP 0164
WP 0443, Vol 3
WP 0181
WP 0447, Vol 3
WP 0185
WP 0451, Vol 3
WP 0190
Equipment Conditions
WP 0270, Vol 2
Engine off (TM 5-3895-385-10)
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Worklight Fails to Operate Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Screed Controller Offline fault
1. Turn keyless engine switch to
indicated on fault screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Attempt to turn on worklights
using keypad (TM 5-3895-385-
10).
3. Check fault screen for SCREED
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0181.
2. If no fault is found, proceed to
next test.
4. Check fault screen for LIGHTS
1. If fault is found, proceed to WP
RELAY fault.
0164.
2. If no fault is found, proceed to
next test.