WORKLIGHT FAILS TO OPERATE
Table 1. Worklight Fails to Operate Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  666    667    668    669    670  671  672    673    674    675    676  
img
. . . .
TM 5-3895-385-23-1
0163
Table 1. Worklight Fails to Operate Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. Check fault screen for RIGHT
1. If fault is found, proceed to WP
CONSOLE LIGHTS KEYPAD
0190.
fault.
2. If no fault is found, proceed to
next test.
6. Check fault screen for LEFT
1. If fault is found, proceed to WP
CONSOLE LIGHTS KEYPAD
0185.
fault.
2. If no fault is found, proceed to
next malfunction.
2. Light bulb faulty.
1. Turn worklights on.
2. Check status of worklight
1. If no worklights are operating,
operation.
proceed to next malfunction.
2. If only the right rear worklight is
malfunctioning, proceed to test
3.
3. If only the left rear worklight is
malfunctioning, proceed to test
4.
4. If only the right screed worklight
is malfunctioning, proceed to test
5.
5. If only the left screed worklight is
malfunctioning, proceed to test
6.
6. If only the right front worklight is
malfunctioning, proceed to test
7.
7. If only the left front worklight is
malfunctioning, proceed to test
8.
3. Measure voltage (WP 0443, Vol
1. If voltage reads below 22 Volts
3) from known good ground to
Direct Current (VDC), turn
W1 J43 pin 1 on main wiring
keyless engine switch to the
harness (WP 0451, Vol 3, Figure
OFF position (TM 5-3895-385-
8).
10), and replace main wiring
harness (WP 0373, Vol 2).
0163-2