LEFT CONVEYOR FAILS TO TURN
Table 1. Left Conveyor Fails to Turn Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  645    646    647    648    649  650  651    652    653    654    655  
img
. . . . . . . . . . . . . .
TM 5-3895-385-23-1
0158
Table 1. Left Conveyor Fails to Turn Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Check fault screen for LEFT
1. If fault is found, proceed to WP
CONVEYOR SPEED COIL fault.
0159.
2. If no fault is found, proceed to
next test.
5. Check fault screen for RIGHT
1. If fault is found, proceed to WP
CONSOLE BEACON KEYPAD
0188.
fault.
2. If no fault is found, proceed to
next test.
6. Check fault screen for LEFT
1. If fault is found, proceed to WP
CONSOLE BEACON KEYPAD
0183.
fault.
2. If no fault is found, proceed to
next test.
7. Check fault screen for RIGHT
1. If fault is found, proceed to WP
CONSOLE HORN KEYPAD
0189.
fault.
2. If no fault is found, proceed to
next test.
8. Check fault screen for LEFT
1. If fault is found, proceed to WP
CONSOLE HORN KEYPAD
0184.
fault.
2. If no fault is found, proceed to
next test.
9. Check fault screen for RIGHT
1. If fault is found, proceed to WP
CONSOLE LIGHTS KEYPAD
0190.
fault.
2. If no fault is found, proceed to
next test.
10.Check fault screen for LEFT
1. If fault is found, proceed to WP
CONSOLE LIGHTS KEYPAD
0184.
fault.
2. If no fault is found, proceed to
next test.
0158-2