TM 5-3895-385-23-1
0158
Table 1. Left Conveyor Fails to Turn Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
11.Check fault screen for RIGHT
1. If fault is found, proceed to WP
SCREED AUG/CONV KEYPAD
fault.
2. If no fault is found, proceed to
next test.
12.Check fault screen for LEFT
1. If fault is found, proceed to WP
SCREED AUG/CONV KEYPAD
fault.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next malfunction.
2. Conveyor drive chain missing or
Check left conveyor drive chain for
1. If damage is found or chain is
damaged.
damage (WP 0419, Vol 2).
missing, replace conveyor drive
chain (WP 0419, Vol 2).
2. If no leak or damage is found,
proceed to next malfunction.
3. Conveyor drive motor leak.
Check left conveyor drive motor and
1. If leaks are found, replace
torque hub for leaks (WP 0419, Vol
damaged component (WP 0419,
2).
Vol 2).
2. If no leak or damage is found,
proceed to next malfunction.
4. Conveyor drive motor hydraulic
Check all conveyor drive motor
1. If leaks or damage is found,
hose leak.
hydraulic hoses and auger motor
replace damaged hydraulic hose
hydraulic hoses for leaks or pinched
(WP 0300, Vol 2 and WP 0298,
hoses (WP 0300, Vol 2 and WP
Vol 2).
0298, Vol 2).
2. If no leak or damage is found,
proceed to next malfunction.
5. Auger malfunction.
1. Start BMPM engine (TM 5-3895-
385-10).
2. Turn left augers on (TM 5-3895-
1. If augers function properly, turn
385-10).
keyless engine switch to the
OFF position (TM 5-3895-385-
10), and proceed to next
malfunction.
0158-3