TM 5-3895-385-23-1
0068
Table 1. SPN#729, FMI#4 ― Low Voltage at Intake Air Heater Signal Circuit -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
kΩ, restore equipment to
original condition, and proceed
to next test.
2. Turn keyless engine switch to
AUX position (TM 5-3895-385-
10), but do not start engine.
Wait for 30 seconds.
3. Check active engine faults
1. If fault code SPN#729, FMI#4 is
screen for fault code SPN#729,
displayed, turn keyless engine
FMI#4.
switch to OFF position (TM 5-
3895-385-10), and replace
ECM (WP 0332, Vol 2).
2. If fault code SPN#729, FMI#4 is
not displayed, turn keyless
engine switch to OFF position
(TM 5-3895-385-10). No fault
present; restore equipment to
original condition.
END OF WORK PACKAGE
0068-4