HIGH VOLTAGE AT SENSOR SUPPLY CIRCUIT NUMBER 2
ENGINE MISFIRE FOR MULTIPLE CYLINDERS -- CONDITION EXISTS

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  325    326    327    328    329  330  331    332    333    334    335  
img
TM 5-3895-385-23-1
0070
Table 1. SPN#1080, FMI#3 ― High Voltage at Sensor Supply Circuit Number 2 -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Circuit response incorrect.
1. Install fuse box (WP 0277, Vol 2).
2. Connect battery cables (WP
0357, Vol 2).
3. Turn keyless engine switch to
AUX position (TM 5-3895-385-
10), but do not start engine. Wait
for 30 seconds.
4. Check active engine faults
1. If fault code SPN#1080, FMI#3 is
screen for fault code SPN#1080,
displayed, turn keyless engine
FMI#3.
switch to OFF position, and
replace ECM (WP 0332, Vol 2).
2. If fault code SPN#1080, FMI#3 is
not displayed, turn keyless engine
switch to OFF position, and repair
or replace ECM harness (WP
0334, Vol 2).
END OF WORK PACKAGE