Figure 1. NATO Slave Receptacle.
Figure 2. EMERGENCY STOP Switch.

Technical Manual For Bituminous Material Paving Machine (Bmpm) Page Navigation
  121    122    123    124    125  126  127    128    129    130    131  
img
.
TM 5-3895-385-10
0008
NORTH ATLANTIC TREATY ORGANIZATION (NATO) SLAVE RECEPTACLE START OPERATION --
CONTINUED.
1. Open engine cover (Figure 1, Item 2).
2. Ensure battery cables (Figure 1, Item 1) are properly connected to battery terminals. Notify field maintenance
if not connected properly.
3. Close engine cover (Figure 1, Item 2).
4. Ensure 24-Volts Direct Current (VDC) power source system is fully charged.
5. Remove protective cover (Figure 1, Item 4) from NATO slave receptacle (Figure 1, Item 3).
6. Connect one end of NATO slave cable to fully-charged 24-VDC system and other end to BMPM NATO slave
receptacle (Figure 1, Item 3).
NOTE
The NATO slave receptacle can be used to start BMPM set when batteries are discharged.
7. Start fully-charged 24-VDC system.
8. Start BMPM (WP 0006).
9. Remove NATO slave cable after BMPM engine starts.
10. Install protective cover (Figure 1, Item 4) onto NATO slave receptacle (Figure 1, Item 3).
END OF TASK