TM 5-3895-385-10
0006
SPRAYDOWN PROCEDURES
Figure 36. Control Pedestal -- Spraydown.
WARNING
Cleaner solution is toxic to eyes, skin, and respiratory tract. Skin and eye protection are required
when working in contact with cleaner solution. Avoid repeated or prolonged contact. Provide
adequate ventilation. Operators are to wash exposed skin and change soaked clothing promptly if
exposed to cleaner solution. Failure to comply may cause injury or death to personnel.
NOTE
Hopper wings should be empty and all excess paving material should be manually removed
from the BMPM before performing spraydown procedure.
The spraydown key LED will be illuminated when spraydown pump is on.
1. Turn keyless engine switch to the AUX position (WP 0004).
2. Press the spraydown key (Figure 36, Item 1) to turn on spraydown.
3. Remove wand handle (Figure 37, Item 1) from storage bracket (Figure 37, Item 4).
4. Unroll the amount of spraydown hose (Figure 37, Item 3) needed from hose reel (Figure 37, Item 2).