TM 5-3895-373-34
2.66.
REPLACE EXTENSION SCREED FRAME - Continued
D.
INSTALL - Continued.
12.
INSTALL SCREED HANDRAIL.
a.
With the help of another person, line up right
leg of screed handrail (23) with mounting holes
in screed frame.
b.
Install lockwasher (25) and flat washer (26)
onto hex head cap screw (24).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact
with
eyes.
If
compound
contacts eyes, flush eyes with water and
get immediate medical attention.
c.
Apply thread locking compound (Item 13,
Appendix B) to threads of hex head cap screw
(24).
d.
Install but do not tighten hex head cap screw
(24) and ground wires (30 and 31) into forward
right hand screw hole on right side handrail
mounting base.
e.
Install lockwasher (25) and flat washer (26)
onto hex head cap screw (24).
f.
Apply thread locking compound (Item 14,
Appendix B) to threads of hex head cap screw
(24).
g.
Install but do not tighten hex head cap screw
(24) and ground wires (27, 28, and 29) into
forward left hand screw hole on left side
handrail mounting base.
h.
Install lockwashers (21) and flat washers (22)
onto hex head cap screws (20).
i.
Apply thread locking compound (Item 14,
Appendix B) to threads of hex head cap
screws (20).
j.
Install hex head cap screws (20) into remaining
screw personnel become dizzy or drowsy
during use, holes on handrail mounting bases.
K
Tighten hex head cap screws (20 and 24) to 37
lb-ft (50 Nm).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in a
well ventilated area. Avoid prolonged
exposure
to
fumes.
If
personnel
become dizzy or drowsy during use, get
immediate medical attention.
l.
Apply electrical insulating varnish to ring
terminals of ground wires (27 through 31).
GO TO NEXT PAGE
2-926